Preliminary Technical Data
TRANSITIONING BETWEEN OPERATING MODES
The operating mode of the ADE7566/ADE7569 is determined
by the power supply connected to V SW . Therefore, changes in
the power supply such as when V SW switches from V DD to V BAT ,
or when V SW switches to V DD , alters the operating mode. This
section describes events that change the operating mode.
Automatic Battery Switchover (PSM0 to PSM1)
If any of the enabled battery switchover events occur (see the
Battery Switchover section), V SW switches to V BAT . This switchover
results in a transition from the PSM0 to PSM1 operating mode.
When battery switchover occurs, the analog circuitry used in
the ADE energy measurement DSP is disabled. To reduce power
consumption, the user code can initiate a transition to PSM2.
Entering Sleep Mode (PSM1 to PSM2)
To reduce power consumption when V SW is connected to V BAT ,
user code can initiate sleep mode, PSM2, by setting Bit 4 in the
Power Control SFR (POWCON, 0xC5) to shut down the MCU
core. Events capable of waking the MCU can be enabled (see the
3.3 V Peripherals and Wake-Up Events section).
ADE7566/ADE7569
Automatic Switch to V DD (PSM1 to PSM0)
If the conditions to switch V SW from V BAT to V DD occur (see the
Battery Switchover section), the operating mode switches to
PSM0. When this switch occurs, the analog circuitry used in the
ADE energy measurement DSP automatically restarts. Note that
code execution continues normally. A software reset can be
performed to start PSM0 code execution at the power-on reset
vector.
USING THE POWER MANAGEMENT FEATURES
Because program flow is different for each operating mode, the
status of V SW must be known at all times. The FVSW bit in the
Power Management Interrupt Flag SFR (IPSMF, 0xF8) indicates
what V SW is connected to. This bit can be used to control program
flow on wake-up. Because code execution always starts at the
power-on reset vector, Bit 6 of the Peripheral Configuration
SFR (PERIPH, 0xF4) can be tested to determine which power
supply is being used and to branch to normal code execution, or
to wake up event code execution. Power supply events can also
occur when the MCU core is active. To be aware of the events
that change what V SW is connected to, use the following guidelines:
Servicing Wake-Up Events (PSM2 to PSM1)
The ADE7566/ADE7569 may need to wake up from PSM2 to
service wake-up events (see the 3.3 V Peripherals and Wake-Up
Events section). PSM1 code execution begins at the power-on
reset vector. After servicing the wake-up event, the ADE7566/
?
?
Enable the battery switchover interrupt (EVSW) if
V SW = V DD at power-up.
Enable the power supply restored interrupt (EPSR) if
V SW = V BAT at power-up.
ADE7569 can return to PSM2 by setting Bit 4 in the Power
Control SFR (POWCON, 0xC5) to shut down the MCU core.
Automatic Switch to V DD (PSM2 to PSM0)
If the conditions to switch V SW from V BAT to V DD occur (see the
Battery Switchover section), the operating mode switches to
PSM0. When this switch occurs, the MCU core and the analog
circuitry used in the ADE energy measurement DSP
automatically restarts. PSM0 code execution begins at the
power-on reset vector.
POWER SUPPLY
RESTORED
An early warning that battery switchover is about to occur is
provided by SAG detection and possibly low V DCIN detection
(see the Battery Switchover section).
For a user-controlled battery switchover, enable automatic
battery switchover on low V DD only. Then, enable the low V DCIN
event to generate the PSM interrupt. When a low V DCIN event
occurs, start data backup. Upon completion of the data backup,
enable battery switchover on low V DCIN . Battery switchover
occurs 30 ms later.
PSMO
NORMAL MODE
V SW CONNECTED TO V DD
AUTOMATIC BATTERY
SWITCHOVER
PSM1
BATTERY MODE
V SW CONNECTED TO V BAT
POWER SUPPLY
RESTORED
WAKEUP
EVENT
USER CODE DIRECTS MCU
TO SHUTDOWN CORE AFTER
SERVICING WAKE-UP EVENT
PSM2
SLEEP MODE
V SW CONNECTED TO V BAT
Figure 28. Transitioning Between Operating Modes
Rev. PrA | Page 33 of 136
相关PDF资料
ADE7752BARWZ-RL IC ENERGY METERING 3PHASE 24SOIC
ADE7755ARSZ IC ENERGY METERING 1PHASE 24SSOP
ADE7757ARNZRL IC ENERGY METERING 1PHASE 16SOIC
ADE7758ARWZRL IC ENERGY METERING 3PHASE 24SOIC
ADE7761AARSZ-RL IC ENERGY METERING 1PHASE 20SSOP
ADE7761BARSZ-RL IC ENERGY METERING 1PHASE 20SSOP
ADE7768ARZ-RL IC ENERGY METERING 1PHASE 16SOIC
ADE7769ARZ-RL IC ENERGY METERING 1PHASE 16SOIC
相关代理商/技术参数
ADE7569ASTZF162 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
ADE7569ASTZF16-RL 功能描述:IC ENERGY METER 1PHASE 64-LQFP RoHS:是 类别:集成电路 (IC) >> PMIC - 能量测量 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:2,500 系列:*
ADE7569ASTZF16-RL2 制造商:AD 制造商全称:Analog Devices 功能描述:Single-Phase Energy Measurement IC with 8052 MCU, RTC, and LCD Driver
ADE7751 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with On-Chip Fault Detection
ADE7751AAN-REF 制造商:AD 制造商全称:Analog Devices 功能描述:Energy Metering IC with On-Chip Fault Detection
ADE7751AN 制造商:Analog Devices 功能描述:Energy Measurement 24-Pin PDIP 制造商:Analog Devices 功能描述:ENERGY MEASUREMENT 24PDIP - Bulk 制造商:Rochester Electronics LLC 功能描述:PRODUCT TO FREQUENCY CONVERTER I.C. - Bulk
ADE7751ARS 制造商:Rochester Electronics LLC 功能描述:PRODUCT TO FREQUENCY CONVERTER I.C. - Bulk 制造商:Analog Devices 功能描述:IC ENERGY METER
ADE7751ARSRL 制造商:Analog Devices 功能描述:Energy Measurement 24-Pin SSOP T/R 制造商:Analog Devices 功能描述:IC ENERGY METER